User Tools

Site Tools


events

UPM_Message

AttributeValueDescription
Name UPM_Message Name of the event
Direction In or OUT Direction of message, in or out from the server
UPM.HouseCode 0-15
UPM.DeviceCode 1-4
UPM.Primary 0-2048 Raw main value of message, normally temperature. Value is (temp + 50) * 16
UPM.Secondary 0-255 Raw secondary value, normally humidity.
UPM.LowBattery 0/1 Signals low battery in device

Nexa_Message

AttributeValueDescription
Name Nexa_Message Name of the event
Direction In or Out Direction of message, in or out from the server
Nexa.HouseCode 0 - 7
Nexa.Button 1 - 8
Nexa.Command 0/1 Off / On

NexaL_Message

AttributeValueDescription
Name NexaL_Message Name of the event
Direction In or Out Direction of message, in or out from the server
NexaL.Address 0 - 67108863
NexaL.Button 1 - 17 Pressed button, 17 is a special “group” button which affects all units on the address
NexaL.Command 0/1 Off / On

Deltronic_Message

AttributeValueDescription
Name Deltronic_Message Name of the event
Direction In or Out Direction of message, in or out from the server
Deltronic.Address 0 - 63
Deltronic.Button 0 - 3
Deltronic.Command 0/1 Off / On

Pronto_Message

AttributeValueDescription
Name Pronto_Message Name of the event
Direction In or Out Direction of message, in or out from the server
Pronto.Message Message The Pronto encoded message string